{"title":"ISO-Series Professional Isolation Transformer (500VA - 1000VA)","description":"\u003cblockquote data-path-to-node=\"5\"\u003e\n\u003ch3 data-path-to-node=\"5,0\"\u003eProfessional Grade Isolation Transformers | ISO-Series\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5,1\"\u003eEngineered for safety, precision, and noise isolation, our \u003cb data-path-to-node=\"5,1\" data-index-in-node=\"59\"\u003eISO-Series\u003c\/b\u003e transformers provide a clean, \"floating\" AC power source for sensitive environments. Whether you are a technician servicing vintage \"hot-chassis\" gear, a lab manager in a university, or an audiophile looking to eliminate ground loops, our transformers deliver the galvanic isolation required for critical applications.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5,2\"\u003e\u003cb data-path-to-node=\"5,2\" data-index-in-node=\"0\"\u003eCore Applications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"5,3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eElectronics Repair:\u003c\/b\u003e Essential safety for servicing vintage radios, tube amplifiers, and televisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,1,0\"\u003e\u003cb data-path-to-node=\"5,3,1,0\" data-index-in-node=\"0\"\u003eLaboratory \u0026amp; Education:\u003c\/b\u003e Safe power for oscilloscopes and test equipment in university and R\u0026amp;D labs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,2,0\"\u003e\u003cb data-path-to-node=\"5,3,2,0\" data-index-in-node=\"0\"\u003eAudio \u0026amp; Music Production:\u003c\/b\u003e Eliminates 60Hz hum and ground loop noise in high-end audio signal chains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,3,0\"\u003e\u003cb data-path-to-node=\"5,3,3,0\" data-index-in-node=\"0\"\u003eIndustrial Manufacturing:\u003c\/b\u003e Protects sensitive controllers and displays from electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"5,4\"\u003e\u003cb data-path-to-node=\"5,4\" data-index-in-node=\"0\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"5,5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eTrue Galvanic Isolation:\u003c\/b\u003e 1:1 ratio 117VAC to 117VAC conversion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,1,0\"\u003e\u003cb data-path-to-node=\"5,5,1,0\" data-index-in-node=\"0\"\u003eSafety First:\u003c\/b\u003e Intentionally ungrounded secondary outputs for a true floating ground (Professional Series).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,2,0\"\u003e\u003cb data-path-to-node=\"5,5,2,0\" data-index-in-node=\"0\"\u003eHigh Capacity:\u003c\/b\u003e Available in 300VA, 500VA, and 1000VA configurations to suit any workbench or rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/blockquote\u003e","products":[{"product_id":"500va-isolation-transformer-117vac-to-117vac","title":"Professional 500VA Isolation Transformer | 117VAC to 117VAC - ISO-500","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3\"\u003eProfessional 500VA Isolation Transformer | 117VAC to 117VAC - ISO-500\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4\"\u003eProduct Overview:\u003c\/b\u003e The ISO-500 is a high-reliability 500VA isolation transformer engineered for laboratory safety and electronic troubleshooting. By providing true galvanic isolation between the AC line and your device under test, this unit creates a \"floating\" output that is essential for technicians using grounded test equipment like oscilloscopes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003eModel:\u003c\/b\u003e ISO-500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eInput Voltage:\u003c\/b\u003e 117V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eOutput Voltage:\u003c\/b\u003e 117V AC (Physically Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eMax Power Rating:\u003c\/b\u003e 500VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,4,0\"\u003eProtection:\u003c\/b\u003e 5 Amp Fast-Blow Fuse (GMA-5A-5)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,5,0\"\u003eOutlets:\u003c\/b\u003e Polarized 2-prong output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,6,0\"\u003eDesign:\u003c\/b\u003e True Isolation (No internal grounding wire connected)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,7,0\"\u003eDimensions:\u003c\/b\u003e 8.3” (L) x 5.6” (W) x 4.3” (H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,8,0\"\u003eWeight:\u003c\/b\u003e 11.7 LBS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7\"\u003eB2B \u0026amp; Industrial Applications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003eOscilloscope Safety:\u003c\/b\u003e Safely probe \"hot\" circuits without risking a short circuit through the scope's Earth ground lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eEngineering R\u0026amp;D:\u003c\/b\u003e Provides a clean, isolated power source for prototyping and sensitive hardware testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eEducational Labs:\u003c\/b\u003e Adds a critical layer of safety for students working with exposed AC circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eAudio Engineering:\u003c\/b\u003e Helps eliminate ground loop interference in sensitive measurement or signal-processing setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eTrue Galvanic Isolation:\u003c\/b\u003e Complete physical separation from the AC mains for enhanced user and equipment protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eFloating Output:\u003c\/b\u003e No input-to-output ground bond, allowing for safe measurements in complex electrical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eRugged Steel Housing:\u003c\/b\u003e Built to withstand the demands of a professional workbench.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eSafety Note:\u003c\/b\u003e This unit is designed for professional laboratory and repair environments. By design, the output is floating and does not provide an Earth ground path. This is intended to allow for safe measurement with grounded test equipment. Users should be trained in isolated power safety protocols.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PHC Enterprise, Inc.","offers":[{"title":"Default Title","offer_id":45514007430,"sku":"ISO-500","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2082\/0601\/files\/ISO-500_Front_2.jpg?v=1777927917"},{"product_id":"1000va-isolation-transformer-117vac-to-117vac","title":"Professional 1000VA Isolation Transformer | 117VAC to 117VAC - ISO-1000","description":"\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eProfessional 1000VA Isolation Transformer | 117VAC to 117VAC - ISO-1000\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eProduct Overview:\u003c\/b\u003e The ISO-1000 is a heavy-duty 1000VA isolation transformer engineered for professional laboratory safety and high-draw electronic troubleshooting. By providing true galvanic isolation between the AC line and your device under test, this unit creates a \"floating\" output—an essential requirement for technicians safely using grounded oscilloscopes on high-power equipment.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,0,0\"\u003eModel:\u003c\/b\u003e ISO-1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,1,0\"\u003eInput Voltage:\u003c\/b\u003e 117V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,2,0\"\u003eOutput Voltage:\u003c\/b\u003e 117V AC (Physically Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eMax Power Rating:\u003c\/b\u003e 1000VA (10 Amps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,4,0\"\u003eProtection:\u003c\/b\u003e 10 Amp Fast-Blow Fuse (GMA-10A-5)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,5,0\"\u003eOutlets:\u003c\/b\u003e Polarized 2-prong output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,6,0\"\u003eDesign:\u003c\/b\u003e True Isolation (Floating output; no internal ground bond)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,7,0\"\u003eDimensions:\u003c\/b\u003e 9.5”(L) x 6.8”(W) x 6”(H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,8,0\"\u003eWeight:\u003c\/b\u003e 18.3 LBS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15\"\u003eIndustrial Applications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,0,0\"\u003eHigh-Power Audio Repair:\u003c\/b\u003e Mandatory safety tool for servicing vintage \"hot chassis\" amplifiers and large-scale radio equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,1,0\"\u003eIndustrial QC \u0026amp; Testing:\u003c\/b\u003e Safely probe high-wattage power supplies and machinery without ground loop risks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,2,0\"\u003eEngineering R\u0026amp;D:\u003c\/b\u003e A robust, isolated power source for testing prototypes and heavy-duty hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16,3,0\"\u003eEducational Labs:\u003c\/b\u003e Provides the high-capacity safety required for university engineering and physics departments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"18\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18,0,0\"\u003eGalvanic Isolation:\u003c\/b\u003e Complete physical separation from AC mains for maximum user and equipment protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18,1,0\"\u003eFloating Output:\u003c\/b\u003e No input-to-output ground bond, allowing for safe measurements with grounded test equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"18,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18,2,0\"\u003eHeavy-Duty Build:\u003c\/b\u003e Reinforced steel housing and industrial-grade copper windings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19\"\u003eSafety Note:\u003c\/b\u003e This unit is designed for professional laboratory and repair environments. By design, the output is floating and does not provide an Earth ground path. This allows for safe measurement with grounded test instruments (oscilloscopes). Users should be trained in isolated power safety protocols.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PHC Enterprise","offers":[{"title":"Default Title","offer_id":45514070598,"sku":"ISO-1000","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2082\/0601\/products\/ISO-1000New_a.jpg?v=1779906069"},{"product_id":"variable-transformer-2-amp-200-watts-0-37vac-output-w-isolation","title":"Isolated Variable Transformer 200VA (2 Amp) | 0–37VAC Output - SC-2T","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eIsolated Variable Transformer 200VA (2 Amp) | 0–37VAC Output - SC-2T\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eProduct Overview:\u003c\/b\u003e The SC-2T is a professional-grade 200VA isolated variable transformer designed for precision electronic testing and lab safety. This model features a high-visibility \u003cb data-path-to-node=\"6\" data-index-in-node=\"184\"\u003eLCD Digital Meter\u003c\/b\u003e for real-time voltage monitoring and an internal isolation transformer that provides a clean 0–37VAC output physically separated from the AC line to ensure technician safety.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e SC-2T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eInput Voltage:\u003c\/b\u003e 120V AC @ 50\/60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eOutput Voltage:\u003c\/b\u003e 0 ~ 37V AC (Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eRated Capacity:\u003c\/b\u003e 200VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eMax Current:\u003c\/b\u003e 2 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eDisplay:\u003c\/b\u003e \u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"9\"\u003eIntegrated LCD Digital Voltmeter\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eProtection:\u003c\/b\u003e Built-in Fuse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eWeight:\u003c\/b\u003e 5.5 LBS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eIndustrial Applications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eElectronics Repair:\u003c\/b\u003e Safely troubleshoot low-voltage circuits with isolated power to prevent equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eResearch \u0026amp; Development:\u003c\/b\u003e Precision-test components requiring specific AC voltages between 0 and 37V.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eEducational Labs:\u003c\/b\u003e Enhances safety for students with both electrical isolation and a clear digital readout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eQuality Control:\u003c\/b\u003e Fast, accurate voltage verification via the digital display for production testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eTrue Isolation:\u003c\/b\u003e Internal transformer for superior user and equipment protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLCD Digital Readout:\u003c\/b\u003e Provides immediate, accurate voltage feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eCompact Safety Design:\u003c\/b\u003e Rugged metal housing with a 3-prong grounded system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eBenchtop Ready:\u003c\/b\u003e Small footprint ideal for crowded technician workstations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003ci data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eNote: Designed for professional benchtop use. Ensure load does not exceed 2 Amps \/200VA.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"17\"\u003e \u003c\/p\u003e","brand":"PHC Enterprise, Inc.","offers":[{"title":"Default Title","offer_id":31524889002097,"sku":"SC-2T","price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2082\/0601\/products\/SC-2T_A.jpg?v=1779906012"},{"product_id":"10a-isolated-variac-1000w-variable-transformer-sc-10t-2","title":"Variable Transformer 10A (1000W) | 0–130VAC Output with Isolation \u0026 LCD Voltmeter - SC-10T-2","description":"\u003cul\u003e\n\u003cli\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eWhy Choose the SC-10T-2?\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eTrue Galvanic Isolation for Safety:\u003c\/b\u003e Essential for safely servicing \"hot chassis\" vintage electronics and radio equipment. By isolating the output from the main AC line, you eliminate the risk of electric shock and equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003ePrecision Monitoring:\u003c\/b\u003e The integrated LCD voltage meter provides real-time, accurate tracking of your output voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eDual AC Outlets:\u003c\/b\u003e Designed for a busy workbench, allowing you to power multiple test devices or your soldering station simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eIndustrial Build:\u003c\/b\u003e Heavy-duty construction featuring a ventilated steel housing designed for continuous, reliable use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIsolation Type:\u003c\/b\u003e True Galvanic Isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003ePart #:\u003c\/b\u003e SC-10T-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eInput Voltage:\u003c\/b\u003e 117VAC @ 50\/60Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eOutput Voltage:\u003c\/b\u003e 0~130VAC Variable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003ePower Rating:\u003c\/b\u003e 1000VA (10 Amp Continuous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eGrounding:\u003c\/b\u003e No grounding pin on AC power cord or internally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eDisplay:\u003c\/b\u003e Digital LCD Volt Meter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eDimensions:\u003c\/b\u003e 9.5”(L) x 6.9”(W) x 7.48”(H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003e\u003cb data-path-to-node=\"8,8,0\" data-index-in-node=\"0\"\u003eWeight:\u003c\/b\u003e 22 LBS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote data-path-to-node=\"9\"\u003e\n\u003cp data-path-to-node=\"9,0\"\u003e\u003cb data-path-to-node=\"9,0\" data-index-in-node=\"0\"\u003eProfessional Engineering Note:\u003c\/b\u003e This unit is intentionally designed without a grounding pin to provide a \"floating\" output. This is the industry-standard safety requirement for servicing vintage \"hot-chassis\" electronics and preventing dangerous ground loops with test equipment like oscilloscopes.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PHC Enterprise, Inc.","offers":[{"title":"Default Title","offer_id":40359142391921,"sku":"SC-10T-2","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2082\/0601\/files\/SC-10T2_2.0a.jpg?v=1763577698"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2082\/0601\/collections\/ISO-500_front.jpg?v=1778106846","url":"https:\/\/www.acdcpowershack.com\/collections\/professional-isolation-transformers-iso-series.oembed","provider":"AC-DC PowerShack","version":"1.0","type":"link"}